Amplified Industries
Producing assets

Plunger controller,
reinvented

Remote control and automatic optimization for plunger lift wells, on the controller already at the well.

High-frequency pressure data and AI keep the well tuned as conditions change.

Two Amplified devices on a plunger lift wellhead in soft daylight, with a centered antenna on the left device

30 minutes

Typical setup per well

3 control modes

To optimize each cycle

10 points per second

Pressure data

Two ways to connect

More control. More arrivals.

Integrate with the controller you have, or use ours to connect directly to your valves.

01 / Integrate with your controller

Keep your existing controller.

Connect Amplified to your existing plunger controller to add remote monitoring, control and optimization to the equipment already on your well.

Existing controller + Amplified

02 / Use our controller

Connect directly to your valves.

Use Amplified’s own plunger controller to connect directly to your valves and manage the well through the Amplified platform.

Amplified controller → Your valves

See every cycle

Every arrival tells a story.

High-frequency pressure data with open, arrival and close stamped on every cycle. This is the data smart mode runs on.

Two plunger cycles, tubing, casing and line pressure on one scale
  • Tubing
  • Casing
  • Line
  • Valve open

Pressure (psi)

05010015020012:3012:4513:0013:15OpenArrivalCloseOpenArrivalClose

Time

Values (2)
CycleOpenArrivalCloseTripPeak tubing
Cycle 112:3012:34:3012:404.5 min146 psi
Cycle 213:0013:04:3013:104.5 min146 psi
Plunger arrival history8 trips · 09/09/26
ArrivalTripDuration against the good windowGrade
21:5309/09/262m 35s
Fast arrival
21:2109/09/262m 44s
Good arrival
20:4809/09/262m 41s
Good arrival
20:1609/09/262m 50s
Good arrival
19:4409/09/263m 02s
Good arrival
19:1209/09/263m 16s
Good arrival
18:4009/09/263m 27s
Slow arrival
18:0809/09/262m 53s
Good arrival

A grade for every trip.

The arrival ledger grades each trip fast, good or slow. Fast and slow trips, plus too many missed arrivals, reach your team by app, SMS or call.

Choose your control method

Three ways to optimize.

Start with the timer logic your operators already know, add pressure-based control, then let the well’s own physics set the pace. Switch from the dashboard at any time.

01

Timer

Shut-in, open and afterflow timers, edited remotely and logged. Recovery control extends shut-in after missed arrivals instead of chasing a plunger that is not coming.

Every well, day one

02

Pressure

Open on the casing-to-tubing differential or on pressure build, so the well cycles when it is ready. Fewer wasted trips, fewer fast hits.

Modbus-class controllers

03

Lift factor

A well-specific SPE model reads high-frequency pressure data and sets the arrival speed that balances production against plunger wear, then adjusts cycle times to hit it.

Only from Amplified

Smart mode

You set the limits.
AI does the tuning.

Pick a method, set your limits and switch on smart mode. Amplified reads every arrival against your fast and slow thresholds and nudges shut-in and afterflow toward the target, one step at a time.

Each change is written to the control history next to the ones your operators make, so you always know who did what and why.

Plunger cycle mode

Shut-in time
19m 00s
Open valve time
6m 00s
Afterflow time
5m 00s

Plunger cycle phases

Current control settings

Smart mode · 30-minute cycle

  • Shut-in time19m 00s
  • Open valve time6m 00s
  • Afterflow time5m 00s

Control history

System AI and operators, one ledger

CommandSettingsUserTime
Update plunger cycleShut-in 19m 00sOpen 6m 00sAfterflow 5m 00sSystem AI9/9/2026, 4:30 PM
Update plunger cycleShut-in 20m 00sOpen 6m 00sAfterflow 5m 00sWade McAllister9/9/2026, 3:07 PM
Update plunger cycleShut-in 23m 00sOpen 6m 00sAfterflow 5m 00sSystem AI9/9/2026, 2:45 PM
Update plunger cycleShut-in 20m 00sOpen 6m 00sAfterflow 5m 00sCody Harlan9/4/2026, 2:03 PM
CloseNot availableCody Harlan9/4/2026, 1:44 PM
Update plunger cycleShut-in 20m 00sOpen 6m 00sAfterflow 5m 00sTravis Whitaker9/3/2026, 1:47 PM
OpenNot availableTravis Whitaker9/3/2026, 1:38 PM
CloseNot availableTravis Whitaker9/2/2026, 1:30 PM
Built for the field

Installed in 30 minutes.

Upgrade your field of legacy controllers in a couple days.

Installed plunger lift system with numbered callouts for the solar kit, gateway, pressure devices, controller and pneumatic valve
  1. 1Solar kit
  2. 2Gateway
  3. 3Tubing and casing pressure devices
  4. 4Your controller + Amplified Plunger Box
  5. 5Pneumatic valve
In your pocket

Your well.
Wherever you are.

Everything on the dashboard is in the Amplified app. Switch modes, change timers, read pressures and take alerts by push, SMS or call.

Illustration of the Amplified app showing plunger well pressures, cycle metrics and control settings
What goes on the well

Every cycle. Analyzed.

Two wireless pressure devices, a gateway, the Amplified Plunger Box and a solar kit. Explore the hardware and take control of the next cycle.

Connected plunger wellHover to explore · select to control
Amplified Plunger BoxConnected

Plunger control

Your controller. Every cycle, in view.

Lift Factor control

Tune the cycle toward a target arrival time using pressure and the last plunger trip.

Cycle settings
Current phaseShut-in
8:00
Shut-inLiftingAfterflow
Production valveClosed
Casing − tubing33.0 psi

Commands apply now. Lift Factor control continues.
Last arrival: 180 sec · Good

Swipe to explore the well. Tap a device for details.

Amplified cloud Live sync · 3 devices connected
Explore the dashboard
Ground levelFlanged wellhead with casing outlets and manual isolation valveExisting controllerTo productionCasingTubingPlunger lift
Produced fluids Wireless dataHover or select a device to explore
Your controller and arrival sensor stay in place. Amplified connects the well.Timer · pressure · lift factor

Works with Timekeeper, Trilift, Flowco, PCS, Megalift and other common controllers, with any arrival sensor.