Connect your LACT unit to Amplified. Track net and gross barrels sent, temperature, pressure, and BS&W from the dashboard or app.

Set alarms on each reading, and keep your sales beside the wells and tanks that produce them.

An Amplified Modbus gateway mounted on a steel post beside a LACT positive-displacement meter with a mechanical barrel counter

Net & gross

Barrels sent, daily and month to date

BS&W alarms

On the limit you set

What Amplified reads

The numbers behind every sale.

Amplified reads your LACT controller continuously, so the volume and quality of the oil leaving the lease are on screen, not on a ticket you see at month end.

  • Net barrels sent

    Temperature-corrected net volume, today, yesterday, and month to date.

  • Gross barrels

    Gross beside net, so you see what the correction took off.

  • BS&W

    Sediment and water content in the oil you sell, reading by reading.

  • Temperature

    Flow-weighted average temperature for each day and each month.

  • Pressure

    Line pressure through the meter run, wherever the controller reports it.

  • Daily and monthly totals

    Yesterday, weekly, and monthly averages, kept with the rest of your production.

Track every sale

Volume, temperature,
and BS&W on one page.

Each month’s net volume builds day by day. Temperature and BS&W sit on the same days, so a wet afternoon is easy to find.

LACT unit, September 1 to October 18
Month-to-date net
1,189 bbl
September net
2,065 bbl
Average temperature
77.1 °F
BS&W alarm limit
1.0%
  • Net
  • Temperature
  • BS&W
Net volume, month to date (bbl)01,0002,000Temperature (°F)4070100BS&W (%)012SeptemberOctober, in progressAlarm limitBS&W alarmSep 1Sep 15Oct 1Oct 15
Alarms

Set your limits.
Hear about it first.

Alarms reach your team by app, SMS, or call, and open a ticket so someone owns the response. How alerts work

01

BS&W

Know when water or sediment climbs past your limit, before the next run ticket says so.

02

Pressure

High and low limits on line pressure through the unit.

03

Temperature

Catch oil running hotter or colder than the range you set.

04

Flow & volume

Hear about it when the unit stops selling, or daily net falls short.

Works with your LACT unit

Any LACT unit with Modbus.

A Modbus gateway mounts beside the unit and reads the controller already on it. Scan its QR code in the app to assign it, and the readings start coming in.

Modbus gatewayModbusLACT unit

Controllers on LACT units today

Temperature averagers, flow computers, and LACT controllers that talk Modbus, for example:

  • LINCO TA-1000 Plus

    Cameron temperature averager

  • ROC800L

    Emerson liquid flow computer

  • FloBoss S600+

    Emerson flow computer

  • Smith Meter microLoad.net

    TechnipFMC preset and LACT controller

Put your sales data to work

Connect your LACT unit
to the rest of your field.

Tell us which controller runs your LACT unit and we will show you what Amplified reads from it.